Owner’s Manual Model 9100 Vehicular Slide Gate Operator P/N 9100-065 REV B, 1/01 Copyright 2000 DoorKing, Inc. All rights reserved. DoorKing,
x Section 4 – Operating Instructions 4.1 Power and Reset Switches...
1 SECTION 1 - INSTALLATION Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with the instruction
2 Figure 3 The Model 9100 operator is designed so that it can be installed in any of the mounting positions shown below. Once the mounting positio
3 1.2.3 REAR POSITION PAD OR POST MOUNT • Set one chain idler at the top position and one chain idler at the center position on the same side of th
4 Pad mounting can be used when the operator will be installed using either the front or rear mounting position. If the operator is to be center mo
5 1.3.2 POST MOUNTED OPERATORS Post mounting can be used when the operator will be installed in any of the three mounting positions, and must be us
6 Prior to mounting the gate operator, be sure that the chain knockouts and chain idlers are set for the mounting position (front, center or rear)
7 1.5.1 FRONT – PAD MOUNT 1. Secure the chain brackets to each end of the gate so that the brackets are level with the top chain knockouts in the
8 1.5.2 FRONT – POST MOUNT 1. Secure the chain brackets to each end of the gate so that the brackets are level with the bottom chain idlers in the
9 1.5.3 REAR – PAD OR POST MOUNT 1. Install an endless idler assembly (p/n 2600-818) at the gate opening between the gate and fence (figure 16, 18)
10 1.5.4 CENTER – POST MOUNT 1. Install an endless idler assembly (p/n 2600-818) at each end of the gate opening (figure 21). Note that the gate tr
11 This DoorKing slide gate operator is shipped with two warning signs. The purpose of the warning signs is to alert uniformed persons, and to remi
13 SECTION 2 – WIRING Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the O
14 Use Table 1 to determine high voltage wire size requirements. The distance shown in the chart is measured in feet from the operator to the power
15 Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Outdo
16 Secondary entrapment protection devices must be installed to insure a safe operating environment and to reduce the risk of entrapment. This oper
17 2.3.2 CONTACT SENSORS • Disconnect power to the gate operator before installing the contact sensors. • Connect the contact sensors as shown below
18 Loops and loop detectors must be installed with this gate operator to prevent the gate from accidentally closing on vehicles that may be in the
19 This gate operator is equipped with outputs from the circuit board that will report operator status to a companion DoorKing Access Control Syste
iii Use this manual with the following model only. Model 9100-080 with circuit board 4602-010. DoorKing, Inc. reserves the right to make changes i
20 2.6.1 ALARM RESET SWITCH The gate operator is equipped with a reset switch that will silence the entrapment alarm and return the operator to no
21 2.7.1 OPERATOR INTERFACE The interface wiring between the two operators requires four (4) 18 AWG wires for control plus two (2) additional 18 AW
22 2.7.2 SECONDARY ENTRAPMENT PROTECTION DEVICE WIRING Secondary entrapment protection for slide gate operators connected in a master / slave confi
23 2.8.1 MAIN TERMINAL 1. RADIO RECEIVER LOW VOLTAGE COMMON 2. RADIO RECEIVER FULL OPEN INPUT 3. RADIO RECEIVER 24 VAC POWER – 250-ma MAX 4. F
24 2.8.2 AUXILIARY TERMINAL The auxiliary terminal is located on the 4602 circuit board just to the right of main terminals 8 and 9. Auxiliary termi
25 SECTION 3 - ADJUSTMENTS The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s)
26 The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various ope
27 3.2.1 SW 1 (LEFT SWITCH) DESCRIPTION AND FUNCTION Switch 1: Set so that the operator cycles open upon initial power up and open command. If the
28 This gate operator does not use any mechanical limit switches or run timers to adjust the open and close positions of the gate. The gate open an
29 This vehicular gate operator is equipped with an inherent (Type A) entrapment sensing system. This system will sense an obstruction in either th
iv Vehicular gate systems provide convenience to their users and limit vehicular traffic onto your property. These systems can produce high levels
30 3.4.2 CLUTCH ADJUSTMENT In addition to the reverse sensitivity adjustment, this operator is equipped with a mechanical slip clutch to further red
31 SECTION 4 – OPERATING INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let childre
32 Under various entrapment conditions the operator will assume either a soft or hard shutdown (alarm) condition. To determine what type of reset
33 4.2.3 HARD SHUTDOWN A hard shutdown condition occurs when the inherent entrapment protection system has sensed two consecutive obstructions befor
34 This operator is equipped with a manual release system that will allow the gate to be pushed open in the event of a power outage or equipment fa
35 4.3.3 FAIL-SECURE MANUAL OPERATION The FAIL-SECURE option locks the gate when primary (AC) power is removed and requires a keyed release to plac
37 SECTION 5 – MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be performed anytime a
38 Have a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of resistance is necessary to p
39 Gate opens a short distance, then stops and reverses. • Check that the clutch is adjusted properly and is not slipping. • Disconnect the gate f
v WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate control
40 MOTOR / BELT ACCESS To gain access to the inside of the gate operator, loosen the two bolts on each side of the electrical panel at the bottom.
41 The following accessory items can be used with the model 9100 slide gate operator. Contact Sensor Contact sensors for use as a secondary entra
42 1/2 HPMotorMotorCapacitorResistorResistorRedBluePowerSwitchWhiteBlackLockSolenoidGreenBrownCircuit Board High Voltage TerminalsBlueBlueRedRedWhit
43
vi Install The Gate Operator Only If: • The operator is appropriate for the usage Class of the application and the gate is within the weight and le
vii This vehicular gate operator is equipped with an inherent (Type A) entrapment sensing system. This system will sense an obstruction in both th
viii GATE – A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that
ix Section 1 – Installation 1.1 Specifications.........................
Manuels d'utilisation et guides de l'utilisateur pour Cartes/adaptateurs d'interface Lava DSERIAL-PCIPARALLEL.
Nous fournissons des manuels en pdf 1 Lava DSERIAL-PCIPARALLEL à télécharger gratuitement par type de document : Fiche technique
marque: Lava | Catégorie: Interface cards/adapters | Taille: 0.06 MB |
Modèles | Type de document |
---|---|
SSerial-PCIe/LP | Guide d'installation Lava SSerial-PCIe/LP, 4 pages |
DSerial-PCIe/LP | Guide d'installation Lava DSerial-PCIe/LP, 4 pages |
DSERIAL-PCIE | Guide d'installation Lava DSerial-PCIe, 4 pages |
DSERIAL-PCI 3.3V | Manuel de l'utilisateur Lava DSerial-PCI 3.3V, 6 pages |
SP-PCIE | Guide d'installation Lava SP-PCIe [en] , 4 pages |
Parallel-PCIe/LP | Guide d'installation Lava Parallel-PCIe/LP, 4 pages |
SSERIAL-PCIE | Guide d'installation Lava SSerial-PCIe, 4 pages |
Kommentare zu diesen Handbüchern