Seite 1 - Owner’s Manual

Owner’s Manual 1838 PC Programmable Multi-Door Access Controller DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310

Seite 2 - 2 1838-065-J-6-08

1.1.1 Mount Information If used to control a door or pedestrian gate, try to locate the access controller as near as possible to the entry point. The

Seite 3

1.2 Memory Chip Installation The access controller is shipped with two memory chips packaged in a separate box inside the shipping container. Th

Seite 4 - TABLE OF CONTENTS

Page 12 1838-065-J-6-08

Seite 5

SECTION 2 – WIRING Prior to installing wiring to the access control system, we suggest that you become familiar with the instructions, illustrati

Seite 6 - IMPORTANT NOTICE

2.1 WIRING GUIDELINES Do not run high voltage (115 V) power lines and communication lines in the same conduit. These should be in separate conduits

Seite 7 - IMPORTANT INFORMATION

MAIN DESCRIPTION 1 Phone Line Connection – 800 ft. maximum with 24 AWG wire; 1600 ft. maximum with 22 AWG wire. 2 Phone Line Connection – 800 f

Seite 8 - FEATURES

2.3 WIRING DETAIL 2.3.1 Controller Only C.O.PHNElevatorControlRS 232ConnectionAuxiliary TerminalsMain TerminalRelay 04 51833, 1834, 1835, 1837, 18

Seite 9 - SECTION 1 - INSTALLATION

2.3.2 Controller & Expansion Boards 1-8 C.O.PHNElevatorControlRS 232ConnectionAuxiliary TerminalsMain TerminalRelay 04 51833, 1835, 1837, 183

Seite 10 - 10 1838-065-J-6-08

2.3.3 Controller & Expansion Boards 1-16 Main Terminal1833, 1835, 1837, 1838 CONTROLLERNOTES: Controller main terminals 15-16-17 = SYSTEM RELAY 1

Seite 11 - 1.2 Memory Chip Installation

2.3.4 Controller and 1838-120 & 121 Remote Call StationsC.O.PHNElevatorControlRS 232ConnectionMain Terminal41838 CONTROLLER123456123123 17161

Seite 12 - 12 1838-065-J-6-08

Page 2 1838-065-J-6-08

Seite 13 - SECTION 2 – WIRING

2.3.5 Controller and 1504-120 & 121 Remote Call StationsC.O.PHNElevatorControlRS 232ConnectionMain Terminal41838 CONTROLLER123456123123 171615141

Seite 14 - 2.1 WIRING GUIDELINES

2.3.6 RS-232 Cable Connection P/N 1818-0401569123456REDBLACKWHITEBROWNGREENSHIELDDOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No.Detail Wiring

Seite 15 - 2.2 TERMINAL DESCRIPTIONS

2.3.7 Postal Lock Box Installation & Wiring – Optional At some locations, such as gated communities, it may be necessary to provide access to th

Seite 16 - 2.3 WIRING DETAIL

SECTION 3 – PROGRAMMING IMPORTANT! Many of the advanced features available with this access control system cannot be programmed from the system

Seite 17 - 1838-065-J-6-08 Page

3.1.2 Programming from the Keypad Follow the programming instructions as described in each section of this manual. The system will prompt you with

Seite 18 - 18 1838-065-J-6-08

3.2 PROGRAMMING WITH A PC Prior to programming the PC Programmable Telephone Entry System with the DoorKing Remote Account Manager for Windows s

Seite 19 - 1838-120/121

3.2.4 Open Tone On or Off The following programming sequence turns the open tone (when the relays activate) either On or Off. This feature is availa

Seite 20 - 1504-120/121

3.3 GENERAL PROGRAMMING Proceed with the programming steps on the following pages only if PC programming will not be used. 3.3.1 Relay Strike

Seite 21

3.3.3 Tone Open Numbers These steps will program the tone open numbers for relays 1 and 2. You will need to enter a four-digit number (see chart bel

Seite 22 - 22 1838-065-J-6-08

3.3.5 Touch-tone / Rotary-dial This programming sequence will set the remote call station to dial out in either a touch-tone or rotary format. G

Seite 23 - SECTION 3 – PROGRAMMING

Use this manual with the following models only. Model 1838 Access Controller, REV F or Higher DoorKing, Inc. reserves the right to make cha

Seite 24 - Page 24 1838-065-J-6-08

3.4 PROGRAMMING PHONE NUMBER NOTE: These programming steps are only used when a DKS 1838-120 or 1838-121 Remote Call Station is connected to the 18

Seite 25 - 3.2 PROGRAMMING WITH A PC

3.4.3 Programming Area Code Program an area code when 10-digit or long distance calling is required. The area code will be entered as a four-digi

Seite 26 - 26 1838-065-J-6-08

3.4.5 Delete Phone Number This programming sequence is used to delete the phone number under a known directory code. 1. Press * 0 1 and enter the fo

Seite 27 - 3.3 GENERAL PROGRAMMING

The PC programmable access control system must be equipped with a MemPLUS chip to program device codes into its memory. Device codes must be fiv

Seite 28 - 28 1838-065-J-6-08

3.6 FOUR-DIGIT ENTRY CODE A DoorKing slave keypad (P/N 1814-075) is required if four-digit entry codes are going to be used to access a door or gate

Seite 29

3.7 ANTI-PASS BACK – 1833, 1835, 1837 only with APB CHIP SET The programming steps below will allow you to set up and program some basic functio

Seite 30 - 30 1838-065-J-6-08

3.8 CONTROL BOARD ADJUSTMENTS DOORKING, INC., INGLEWOOD, CA 90301Date: Dwg. No.1838 Board AdjustmentsRev.Title:12/06BM1838-065-4123141312111098765

Seite 31

3.8.1 Master Code Switch 1. The master code switch is left in the off position for normal operation. Turn the master code switch on when setti

Seite 32 - 32 1838-065-J-6-08

Note: 3.8.4 and 3.8.5 are only applicable if a Remote Call Station is connected to the 1838 controller. 3.8.4 Speaker Volume, Microphone and Feedbac

Seite 33

SECTION 4 – OPERATING INSTRUCTIONS 4.1 USER INSTRUCTIONS 4.1.1 Card Access Card access is provided by card readers or automatic vehicle Identifi

Seite 34 - 3.6 FOUR-DIGIT ENTRY CODE

TABLE OF CONTENTS Preface Important Notices...

Seite 35

4.2 SYSTEM ADMINISTRATOR INSTRUCTIONS The system administrator can perform the following operations from a remote location using a touch-tone telepho

Seite 36 - 36 1838-065-J-6-08

SECTION 5 – MAINTENANCE The DoorKing 1838 access controller is essentially a maintenance free device. When the unit is properly installed, it sh

Seite 37

SYMPTON POSSIBLE SOLUTION(S) Cannot get into programming mode. Wrong master code entered. Start over. Waiting too long between pushing buttons. Ente

Seite 38 - 38 1838-065-J-6-08

SYMPTON POSSIBLE SOLUTION(S) Four-digit entry codes will not work. Forgetting to press # first. Re-program the entry code ranges (3.6.3). Entry co

Seite 39 - 4.1 USER INSTRUCTIONS

5.1.2 Floor, Elevator, Security Level Test Programming This programming sequence is included for troubleshooting the elevator control board(s) only.

Seite 40 - 40 1838-065-J-6-08

5.1.4 Elevator Board / Floor Hardware Test This testing sequence will allow you to check activation of individual relays on the elevator control

Seite 41 - SECTION 5 – MAINTENANCE

5.2 ACCESSORIES Card Readers A variety of DKS, AWID and HID proximity readers are available for use with the 1838 controller. Most 26-bit card rea

Seite 42 - SYMPTON POSSIBLE SOLUTION(S)

5.3 LOG TABLES Complete the information in the tables on the following pages to maintain a record of the information that has been programmed int

Seite 43

NAME PHONE NUMBER DIR CODE ENT CODE DEVICE CODE SEC LEVEL FL ER

Seite 44 - 44 1838-065-J-6-08

1838-065-J-6-08 Page 49

Seite 45

3.5 Device Codes 3.5.1 Programming Device Codes ...

Seite 46 - 5.2 ACCESSORIES

IMPORTANT NOTICE FCC - UNITED STATES This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Par

Seite 47 - 5.3 LOG TABLES

IMPORTANT INFORMATION • Prior to beginning the installation of the access control system, we suggest that you become familiar with the instructi

Seite 48 - Page 48 1838-065-J-6-08

FEATURES • Can provide service for up to 3000 system users. • Can store up to 8000 card, transmitter or digital PIN codes. • Can interface with DK

Seite 49

SECTION 1 - INSTALLATION If you are going to use a telephone line with this controller, order it at least two weeks prior to the planned installa